Please use this identifier to cite or link to this item:
http://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/9007
Title: | Best Placement of Shear Walls In an RCC Space Frame Based on Seismic Response |
Authors: | Sud, Anshul Shekhawat, Raghav Singh Dhiman, Poonam |
Keywords: | Seismic resistance Shear wall Base shear Storey drift |
Issue Date: | 2014 |
Publisher: | Jaypee University of Information Technology, Solan, H.P. |
Abstract: | Shear walls are one of the most basic lateral load resisting elements in an earthquake resistant building. To avoid torsion in buildings, shear walls must be placed symmetrically in plan. In this paper, a five-storey RC building located in seismic zone-V is considered with four shear walls. Five different configurations of shear walls viz. bare frame, shear wall symmetrically placed at exterior bays (centrally), at core and adjacently placed in exterior of the building, are considered. These frames are analyzed for seismic forces to assess performance in terms of base shear, storey drift, member forces and joint displacements. The frame with shear walls at core and centrally placed at exterior bays showed significant reduction of order 29% to 83% in lateral displacement. The reduction in bending moments is approximately 70% to 85% for interior and perimeter columns respectively. Shear and axial forces in columns have reduced by 86% and 45% respectively. Based on such results, the best placement of shear walls in building plan is suggested. |
URI: | http://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/9007 |
Appears in Collections: | Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Best Placement of Shear Walls In an RCC Space Frame Based on Seismic Response.pdf | 301.92 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.