Please use this identifier to cite or link to this item: http://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/8917
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJala, Sudheer Kumar-
dc.contributor.authorRawat, Saurabh-
dc.contributor.authorGupta, Ashok Kumar-
dc.date.accessioned2023-01-03T11:32:04Z-
dc.date.available2023-01-03T11:32:04Z-
dc.date.issued2020-
dc.identifier.urihttp://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/8917-
dc.description.abstractWeak confinement governs the bulging failure of granular columns. Pervious concrete columns have granular columns like drainage with stiffness of concrete column are thus independent of the confinement from the weak surrounding soil can be treated as an alternative solution. Moreover, it is well established that under-reaming bulb enhances the bearing resistance to the pile shaft. Therefore, the present experimental and analytical study investigates circular pervious concrete column (CPCC) and under-reamed pervious concrete column (UPCC) in improving the bearing capacity of loose pond ash fill. CPCC and UPCC are constructed in a model pond ash fill subjected to vertical loading. The load-carrying capacity, settlement failure mechanism, and consolidation parameters were examined. Theoretical analysis for evaluating the load-carrying improvement factor (LCF) with nondimensional parametric variation of area replacement ratio (Ra), underreamed bulb ratio (Br), and length ratio of the column (RL) was also done. Efficacy of CPCC was also numerically studied (Plaxis 3D). Experimental results show that the vertical settlement is reduced by 52.8% with CPCC and UPCC. UPCC renders higher load-carrying capacity than CPCC. Both CPCC and UPCC undergo deformation at depth of 4D during failure. For the same area replacement ratio (Ra), the experimental and theoretically computed values are found in good agreement. The rate of consolidation is reduced from 53 to 23 days by using CPCC signifying its drainage potentialen_US
dc.language.isoenen_US
dc.publisherJaypee University of Information Technology, Solan, H.P.en_US
dc.subjectPervious concrete columnen_US
dc.subjectUnderreameden_US
dc.subjectPond ashen_US
dc.subjectBulb ratioen_US
dc.subjectConsolidationen_US
dc.titleEffect of Underreamed Pervious Concrete Columns on Load-Carrying Capacity of Loose Cohesionless Soilsen_US
dc.typeArticleen_US
Appears in Collections:Journal Articles



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.