Please use this identifier to cite or link to this item: http://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/6518
Title: Effect of Hooked Steel Fibres On Properties of Concrete
Authors: Jassal, Himanshu
Rajput, Utsav
Shukla, Abhilash [Guided by]
Keywords: OPC
Fibre mechanism
Steel fibres
Issue Date: 2017
Publisher: Jaypee University of Information Technology, Solan, H.P.
Abstract: Bond cement is the most widely utilized development material on the planet. The explanation behind its broad utilize is that it gives great workability and can be formed to subterranean insect shape. Standard bond concrete has a low rigidity, restricted flexibility and little imperviousness to splitting. Inside smaller scale splits, prompting fragile disappointment of cement. In this current age, structural building developments have their own basic and strength necessities, each structure has its own proposed reason and henceforth to meet the reason, adjustment in conventional bond concrete has turned out to be required. It has been found that diverse kind of filaments included particular rate to concrete enhances the mechanical properties, solidness and serviceability of the structure. It is currently settled that one of the critical properties of Steel Fiber Reinforced Concrete (SFRC) is its better resistance than breaking and split engendering. In this postulation impact of filaments on quality of cement for M30 review have been considered by shifting the viewpoint proportion of strands in cement. Fiber viewpoint proportion was changed by 50 and 80. Assist the impact of strands on the quality of cement for M30 review has been examined by changing the rate of filaments in the solid. Fiber content shifted by 0%, 0.5%, 1%, 1.5%, 2% and 2.5%.Cubes of size 150x150x150mm to check the compressive quality, light emissions 500x100x100mm for checking flexural quality and chamber of size 100x200mm for checking the split rigidity were threw. All examples were cured for 7 and 28 days before pounding. The aftereffects of fiber strengthened cement for 7 days and 28 days curing with differed angle proportion of fiber were contemplated and it has been found that there is huge quality change in steel fiber fortified cement. Additionally, it has been watched that with the expansion in fiber perspective proportion builds the quality of cement.
URI: http://ir.juit.ac.in:8080/jspui/jspui/handle/123456789/6518
Appears in Collections:B.Tech. Project Reports

Files in This Item:
File Description SizeFormat 
Effect of Hooked Steel Fibers on Properties of Concrete.pdf3.14 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.